Gas Furnace Sediment Trap

What Is A Sediment Trap Jmc Bay Area Building Inspection Services

What Is A Sediment Trap Jmc Bay Area Building Inspection Services

Sediment Trap Nations Home Inspections Inc

Sediment Trap Nations Home Inspections Inc

Sediment Traps Drip Legs Nonprofit Home Inspections

Sediment Traps Drip Legs Nonprofit Home Inspections

What Is A Sediment Trap What Are They For Wilson Home Inspections

What Is A Sediment Trap What Are They For Wilson Home Inspections

Sediment Trap At Gas Furnace Inspection Gallery Internachi

Sediment Trap At Gas Furnace Inspection Gallery Internachi

What Is A Drip Leg Or Sediment Trap Blue Palmetto Home Inspection

What Is A Drip Leg Or Sediment Trap Blue Palmetto Home Inspection

What Is A Drip Leg Or Sediment Trap Blue Palmetto Home Inspection

Black cap 1 2 in.

Gas furnace sediment trap.

Improperly installed sediment trap on new gas tankless water heater. Missing sediment trap on gas water heater. Black tee 1 2 in. Gas piping installed underground shall be a minimum of 12 in depth 18 where external damage could.

In the above image the trap is perpendicular to the flow of gas. Black nipple 1 2 in. Most water heaters do not have a sediment trap in them. Did the plumber possibly leave it in case you wanted to add to the line.

He has a horizontal run of 1 gas line actually several going to rooftop package units and he just put a tee right in the middle of the horizontal run with a nipple and cap stemming down from it. Handy kit contains everything you need to build a sediment trap onto your home s water heater. Drip leg drip leg and sediment trap are often used interchangeably but they are really two different things. The most frequent improperly configured sediment trap is where the gas supply connects to a tee fitting installed with the tee tap facing down the gas supply is connected to one end of the horizontal tee the appliance is connected to the other end of the horizontal tee and a short nipple is installed into the down facing tee tap the nipple.

Sediment trap cpc 1212 8 a sediment traps is required at each water heater boiler and furnace downstream of the appliance shut off valve and as close to inlet of the equipment as practical. Gas fittings and nipples what s included. It is actually a very useful component of the gas line known as a sediment trap. Sediment traps are intentionally installed to help prevent sediment in the gas piping from getting into the gas valve or burner area of an appliance and fouling things up.

Have you ever looked at your gas furnace or gas water heater and wondered what the short piece of gas pipe going to nothing was for. Gas leak detector spray csa yellow gas thread seal tape 1 2 in. Drip legs technically call just a drip are installed to collect condensation in a gas piping system so they are installed in a low point to prevent condensation from running back into the gas meter. Different areas have different contaminants in the gas and the traps help catch these.

Hi everyone i am the local mechanical inspector in my city. The nipple and cap should be directly down in the directional flow of the gas line.

Sediment Trap And Drip Leg On Water Heaters Purpose And Proper Installation Buyers Ask

Sediment Trap And Drip Leg On Water Heaters Purpose And Proper Installation Buyers Ask

Gas Line Sediment Trap Or Escape Hatch

Gas Line Sediment Trap Or Escape Hatch

How To Install Water Heater Sediment Trap Easy Youtube

How To Install Water Heater Sediment Trap Easy Youtube

Drip Leg Vs Sediment Trap Space City Inspections Webster Clear Lake Houston Pearland League City Alvin Seabrook Texas

Drip Leg Vs Sediment Trap Space City Inspections Webster Clear Lake Houston Pearland League City Alvin Seabrook Texas