Page 2 high humidity or dripping water m36122 dripping water can cause the control to fail.
Honeywell water heater gas control valve manual.
The honeywell valve uses a thermopile instead of a thermocouple as did previous designs.
Sequence of operations wv4460e.
When referring to your water heater always have the information listed on the data plate readily available.
Maximum torque on the outlet is 30 ft lbs.
Water heaters covered by this handbook are equipped with honeywell gas control valve thermostats.
Gas regulation and manual valve features intermittent spark to pilot ignition flame supervision using flame rectification sensing through the spark rod.
The wt8840 water heater control is designed for use 0 5 psi 14 0 in.
The wv4460e water heater control system is designed for power vent water heater applications.
Maximum torque on the inlet is 40 ft lbs.
Page 7 wv4460e power vent water heater controls perform gas leak test gas input and burner ignition check and adjustment 1.
Heat on the thermopile generates 750 to 900 millivolts open circuit.
Check the full rate manifold pressure listed on the warning appliance nameplate.
The wv4460e provides these features.
Connect the pipe to the water heater control inlet and outlet.
Position compression fitting in pilot outlet and engage threads.
Unpacking the water heater warning excessive weight hazard.
Use a wrench on the square end of the water heater control.
W c maximum inlet pressure in standing pilot applications using an immersion allowed for proper operation.